1771-OW16 | Allen Bradley 1771 Digital Relay Contact Output Module
Наличие неизвестно

1771-OW16 | Allen Bradley 1771 Digital Relay Contact Output Module

USD 1 455.00
Артикул 1771-OW16
ID каталога 419
Наличие Estimated Lead Time: 10 - 12 Weeks
Розничная цена USD 1 712.00

Описание

Part Number : 1771-OW16Model1771-OW16Output per module16Module Location 1771 -A1B thru -A4B I/O Chassis; 1771 -AM1 or AM2Voltage Rating24-250V ac (rms), 47-63Hz; 24-150V dcPower Rating?dc: 80 Watts per output (max); 1280 Watts per module (max)ac: 500 VA per output (max); 1440 VA per module (max)cos 0.4Current Rating (maximum per channel)?ac: 2A per output at rated powerdc: 2A per output at 40V; 1A per output at 150V0.5A per output at 100V; 0.25A per output at 150VMaximum Surge Currentdc: 2A maximum per output (at rated power);ac: Refer to Table A belowMinimum Contact Load10 mAOperate/Release Time10ms maximum; 5ms (?1ms) typicalBounce Time Maximum4msSwitching Frequency Maximum1/3 Hz @maximum loadExpected Life of Electrical Contacts300K operations @ 25?C (cos 1)Power DissipationAll relays off: 0.015 Watts; All relays on: 6.55 WattsThermal DissipationAll relays off: 0.05 BTU/hr; All relays on: 22.24 BTU/hrBackplane Current1.3A maximumMaximum Cable Length1000ft (304.8m)Isolation Voltage1500V ac for 1 second customer side to system side;1500V ac for 1 second channel to channel;relay rated 4000V coil to contactConductors Wire Size: Category:14 gauge (2mm?) stranded maximum?3/64 inch (1.2mm) insulation maximum14Environmental Conditions Operational Temp. Storage Temperature Relative Humidity0? to 60?C (32? to 140?F)-40? to 85?C (-40? to 185?F)5 to 95% (without condensation)KeyingBetween 2 and 4Between 32 and 34Field Wiring ArmCatalog Number 1771-WNWiring Arm Screw Torque7-9 inch-poundsAgency Certification (when product or packaging is marked) CSA certified CSA Class I, Division 2, Groups A, B, C, D certified UL listed CE marked for all applicable directivesInstallation data1771-2.206(1) An individual output should not be subjected to high power loads and then be required to run low power loads.(2) Output current maximum per module is limited by the maximum output power rating.(3) 14 gauge wire connected to all terminals may not allow the field wiring arm cover to close. A smaller wire size may be required.(4) You use this conductor category information for planning conductor routing as described in the system-level installation manual.Estimated Lead Time : 10 - 12 WeeksShipping Weight : 2.5 Kg